    TROLMASTER - HYDRO X CO2 CONTROL STATION

    The TrolMaster DSC-2 CO2 control / device module allows user to easily connect and control standard supplemental CO2 devices or CO2 exhaust controls to the Hydro-x. Any CO2 device that is 10-amps @ 240 volts or less can be controlled by the DSC-2

    SPECIFICATIONS:

    Input Voltage: 100~240 VAC, 50/60Hz

    LED status:
    * Blinking green FAST: If the LED is blinking quickly, that means the module has not been addressed to the controller OR that module does not have a good connection to the controller. *Pressing the small button on the module will address/link the module when first installed.
    * Blinking green SLOW: If you see a slowly blinking green LED, that means the module is addressed and connected to the controller, and the module is currently turned OFF.
    * SOLID green: If you see the LED is on solid (no blinking) that means the modules are addressed, connected and currently turned ON.
    * Blinking red: If you see the LED change to blinking red, that means the module has been overloaded. To reset the overload unplug the module from the power.

    TrolMaster Hydro-X Co2 Device Station DSC-2A

      Product form

      TROLMASTER - HYDRO X CO2 CONTROL STATION The TrolMaster DSC-2 CO2 control / device module allows user to easily connect...

      $230.00



        Description

        TROLMASTER - HYDRO X CO2 CONTROL STATION

        The TrolMaster DSC-2 CO2 control / device module allows user to easily connect and control standard supplemental CO2 devices or CO2 exhaust controls to the Hydro-x. Any CO2 device that is 10-amps @ 240 volts or less can be controlled by the DSC-2

        SPECIFICATIONS:

        Input Voltage: 100~240 VAC, 50/60Hz

        LED status:
        * Blinking green FAST: If the LED is blinking quickly, that means the module has not been addressed to the controller OR that module does not have a good connection to the controller. *Pressing the small button on the module will address/link the module when first installed.
        * Blinking green SLOW: If you see a slowly blinking green LED, that means the module is addressed and connected to the controller, and the module is currently turned OFF.
        * SOLID green: If you see the LED is on solid (no blinking) that means the modules are addressed, connected and currently turned ON.
        * Blinking red: If you see the LED change to blinking red, that means the module has been overloaded. To reset the overload unplug the module from the power.